  • MODEL
  • FEATURES
  • TRANSMITTER SPECIFICATION
  • RECEIVER SPECIFICATION
WIRELESS DEADMAN SERIES TRIGGER SWITCH RADIO REMOTE CONTROLS

Model # FHSRDM

Developed specifically for industrial applications requiring positive operator-to-machine contact. A wireless trigger-switch is used to send RF command signals to the pump. Operator is unencumbered by cables and wires normally used in 'deadman' fueling operations. System incorporates a secure frequency hopping, spread-spectrum radio link that is virtually immune to outside electrical or RF interference. Operations fail safe (shutdown) with any loss of signal from transmitter. Rechargeable transmitter delivers 30hrs of continuous use between charges (12/24VDC charger supplied).

  • *'Safety Timer' software available to limit switch closure duration prior to automatic shut-off
  • This feature requires periodic trigger pulse by operator to maintain receiver 'on' condition.
  • Up to eleven other command functions available per customer requirements
  • Modular quick-connect components allow for easy installation and field service
  • Pre-wired solenoids are available for Pneumatic, Hydraulic, or Hose Reel control interface
img

120/240VAC FUELING CABINET SYSTEMS

img

120/240VAC FUELING CABINET SYSTEMS

img

120/240VAC DIN RAIL COMPONENTS

Examples of Additional Control Button options below:

    • HOSE REEL(s) option allows remote Unwind and/or Rewind control greatly reducing effort required to pull the hose off the reel.
    • Potential injury is reduced and productivity is increased through easier hose handling.
    • Easy to install prewired hose reel motor solenoids and 70Amp breaker included with this option.
    • System design prevents Unwind and Rewind circuits from being energized at the same time

    • PTO(s) or PUMP option extends pump life and increases safety by allowing operator to engage and disengage the PTO and PUMP from hose end at customer's storage tank.
    • Truck PTO shaft is not turning, pump is not running in by-pass, and hose is not charged unless connected to the customers tank.
    • PTO connection can be electric, pneumatic, "hot shift" or "clutch shift".
    • Remote PTO DELAY option automatically opens tank internal valve 5 seconds prior to engaging PTO allowing pump and product lines to equalize pressure.
    • This feature prevents an excess flow 'slug' situation which when happens, starves the pump of product, and may lead to pump failure.

    • Engine RPM or THROTTLE option allows operator to increase/ decrease truck engine RPM and corresponding pump volume from the customers tank/ hose-end of the delivery.
    • Operator can begin delivery process, ensure product is flowing safely, then increase pump speed until tank is nearly full.
    • Connections are available for any electronic or mechanical engine control system.

    • ENABLE option can be specified to create a 'two-step' process for activating certain buttons to further prevent unintended button operation.

  • EMERGENCY STOP feature closes all tank valves, and kills the truck engine and pump.
  • BASE's 'safety latched' signal causes the tank valves and pump to remain inoperative until a manual system reset is performed.
  • Pressing the E-Stop button repeatedly will send the same 'shut-down' signal.
  • This system meets International regulatory requirements and is available for all types of pneumatic, cable operated or "Flowmatic" type tank valves and all truck engines.
img
img

TRANSMITTER SPECIFICATIONS

  • FREQUENCY OF OPERATION . . 902-928mHz FHSS (433.92mHz, 869.7mHz & 2.4GHz radios available)
  • TRANSMITTER POWER . . . . . . 100mW
  • METHOD OF TRANSMISSION . . 56 bit DES encryption key
  • ANTENNA . . . . . . . . . . . . . Internal 'on card' PCB mount (no visible antennas to damage)
  • NORMAL RANGE . . . . . . . . . Up to 500 feet (higher power available)
  • FCC APPROVAL # . . . . . . . . . KQLAC4490-100 (non-licensed)
  • CONSTRUCTION . . . . . . . . . Rugged weatherproof polymer enclosure
  • TEMPERATURE SPECIFICATION . minus 20 F to 185 F
  • BATTERY LIFE . . . . . . . . . . . 30hrs of continuous use w/audible low battery warning and flashing LED indicator
  • BATTERY TYPE . . . . . . . . . . . Rechargeable Lithium Ion cell with 12/24VDC charger
img

• ROHS LEAD-FREE COMPLIANT

RECEIVER SPECIFICATIONS

  • POWER SUPPLY . . . . . . . . . . 12/24VDC (Optional 120VAC systems available)
  • CURRENT LOAD . . . . . . . . . Up to 4Amps per channel or10Amps total
  • CONSTRUCTION . . . . . . . . . Water resistant, impact resistant polycarbonate(external mount if required).
  • ANTENNA . . . . . . . . . . . . . Internally protected and encased (external antenna/coax available)
  • WIRING CONNECTIONS . . . . Pre-wired to OEM requirements, quick connect fittings supplied
  • PROGRAMMING MODES . . . . . Up to 12 programmable channels including: Latched,momentary, Safety and *SAFETY TIMER programming modes custom programming available)
  • SERIAL COMMUNICATION . . . Optional CAN bus interface available

ROHS LEAD-FREE COMPLIANT